Property guide
Solar Panels on Post-1965 Homes
Trussed rafter roofs, concrete interlocking tile and modern electrics — the most straightforward housing stock to work on.
What characterises post-1965 housing
From the mid-1960s onwards, British house roofs changed fundamentally. The cut roof — rafters, purlins and struts assembled on site by a carpenter — was replaced almost entirely by the trussed rafter: prefabricated triangulated frames, delivered to site, craned into place at regular centres and braced together.
At the same time the covering standardised on concrete interlocking tile, and the electrical installation moved to PVC cable, a modern earthing arrangement and a consumer unit that is either current or straightforwardly replaceable.
For solar work this is the easiest housing stock in the country. Most of the difficulty on older properties simply is not present.
The trussed roof is a system
This is the key structural point and it changes how the array is fixed. A trussed rafter roof is not a collection of independent rafters; it is an engineered assembly where each truss shares load with its neighbours through the bracing and the tile battens, and every member is sized for a specific set of forces.
Two consequences follow. First, anchors go into the truss rafter members — the top chords — and the array load is spread across as many trusses as possible rather than concentrated on a few. Second, nothing gets cut, notched or drilled. A gang-nail plate that has been disturbed or a web that has been trimmed for a cable run is a structural alteration, and there is no spare capacity built in.
The compensation is that truss centres are regular, usually at 600mm. Set-out is predictable, rail spans are consistent, and the array can be laid out to line up with the structure rather than fighting it.
Covering and membrane
Concrete interlocking tiles are the most forgiving covering we work on. They lift cleanly, the hook detail is well established, the tile relieves and sits back flat, and spares are available. Older concrete tiles do become brittle with age, and a roof of 1970s vintage will yield some breakages, but nothing like a slate or plain clay roof.
Beneath the tiles, the membrane type tells us how to proceed. Bitumen felt from the 1960s and 70s is stiff and perishes, tearing where it is disturbed at a fixing point. Modern breathable membranes are more tolerant but are part of the roof ventilation design and should not be punctured beyond the fixing itself. Either way, penetrations get dressed.
Layout, electrics and services
Roof shapes are simpler here — often a plain gable with a single large slope — which usually means a bigger, tidier array than an equivalent interwar house.
Loft space is the trade-off. Truss webs cut the loft into compartments and there is rarely a clear run or a sensible standing area, so inverter position needs planning around access for future service. On semis and terraces, cable routing has to respect the party wall and the fire separation at the head of it.
Electrically, boards are usually modern or easily replaced, earthing is conventional and supplies are typically adequate for an array with room for storage later. Generation above 16A per phase — roughly 3.68kW single phase — needs G99 approval before installation rather than a G98 notification afterwards.
Limitations
Some 1970s and 80s estates used low-pitch roofs that reduce winter yield. Some developments carry covenants restricting road-facing alterations. And a roof that has had trusses cut for a loft conversion needs a proper structural look before anything is added to it.
What we check on this type of property
- Trussed roofs are engineered as a system, so fixings must land in truss members
- Truss centres are regular, which makes array set-out straightforward
- Concrete interlocking tiles are robust and the easiest covering to work with
- Breathable versus bitumen membrane changes how the roof is opened and reinstated
- Party wall positions and fire separation affect cable routing on semis and terraces
- Estate covenants can restrict alterations visible from the road
- Trusses are not designed to be cut or notched for cable runs
- Loft space is obstructed by webs, limiting where an inverter can be sited
Common questions
Can a trussed roof take solar panels?
Yes, in the great majority of cases. A trussed rafter roof is a designed structure with a known capacity, and a domestic array is a modest additional load spread across many trusses. What matters is that the anchors bolt into the truss rafter members themselves and that the load is distributed rather than concentrated. Where a roof has been altered — a truss cut for a loft conversion or a hatch enlarged — we look at it more carefully.
Why can nothing be cut or notched?
A truss works as a triangulated frame where every member and every gang-nail plate is carrying a calculated force. Cutting a web or notching a chord to pass a cable through takes capacity out of a system that was designed with none to spare. Cables are routed around and clipped, never through, and we would rather take a longer route than compromise a member.
Does the roofing membrane matter?
It affects the method. Older bitumen felt is stiff, degrades with age and tears rather than stretches, so tiles come off and go back with more care. Modern breathable membranes are more forgiving but must not be punctured carelessly or the roof ventilation strategy is undermined. Either way, any tear at a fixing point gets dressed properly rather than left.
Do estate covenants stop solar?
Occasionally they restrict what can be done to elevations visible from the road, particularly on newer developments with a management company. It is a private legal restriction rather than a planning matter, so permitted development rights do not override it. It is worth checking your title deeds if your estate has a residents association or a maintenance charge.
Related services
- Solar panel installationSurvey, design, roof works, electrical works and commissioning for a domestic solar PV system.
- Solar and battery systemsPanels, hybrid inverter and storage designed as one system, on one scaffold, with one commissioning.
- Battery storage installationHome battery systems sized against your consumption, sited properly and commissioned with the tariff in mind.
- EV charger installationHome charge points installed with a proper load assessment, PEN fault protection and solar-aware scheduling.
The technology behind it
- Solar panelsWhat a domestic solar panel is, how it is built, and which specifications on the datasheet actually matter.
- Monocrystalline panelsThe cell technology used in almost every domestic installation, and what half-cut cells actually change on a shaded roof.
- String invertersThe conventional central inverter: how strings are designed, where it is the best value, and where it is the wrong choice.
- Mounting systemsHooks, rails, clamps and fixings — the part of the installation that decides whether the roof stays watertight.
Property and roof guides
- Tile roofsConcrete interlocking, clay pantile and plain tile — the most common covering we work on, and the most forgiving.
- New build homesRetrofitting or extending solar on a new build — structural warranty notification, shallow pitches, interrupted roof planes and covenants.
- East-west roofsLess annual total than south, a flatter daily curve, higher self-consumption — and a design that pairs naturally with storage.
See it on a real installation
Further reading
- How many solar panels do I need?Why panel count is set by your electricity consumption and the usable area of your roof, not by the size of your house.
- What happens during a solar surveyWhat a surveyor measures, inspects and asks about, and why a quotation without a survey is unreliable.
- Solar panels and EPC ratingsHow solar is treated in an EPC assessment, why the improvement varies, and what an assessor needs to see.
Where we work
Information reviewed on 2026-08-23.
Find out what your property can take
Every design starts with a survey of the actual roof, structure and electrics rather than an assumption about the property type.
Tell us about your property
No obligation. We will review the details, come back to arrange the next step, and issue a written design and fixed quotation before anything is agreed.
Prefer to talk? Call 0118 227 7444.